<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a"><p>An ionization chamber for online beam monitoring has been designed and built. To read out the generated<br>
ion current, a two-staged transimpedance amplifier circuit has been designed.</p>
<p>X-ray irradiation was conducted using the X-ray tube that is present at ETP.<br>
Proton irradiation was conducted at the CMS beamline of the CYRC&eacute; cyclotron at IPHC, Strasbourg.</p></subfield>
</datafield>
<datafield tag="100" ind1=" " ind2=" ">
<subfield code="a">Elicabuk, Umut</subfield>
<subfield code="u">KIT/ETP</subfield>
</datafield>
<controlfield tag="001">22080</controlfield>
<datafield tag="245" ind1=" " ind2=" ">
<subfield code="a">Development of an Iterative Irradiation Setup and Online Beam Monitor for Silicon Sensor Irradiation Studies</subfield>
</datafield>
<datafield tag="856" ind1="4" ind2=" ">
<subfield code="s">43328977</subfield>
<subfield code="u">https://publish.etp.kit.edu/record/22080/files/Elicabuk-Umut-Nov21.pdf</subfield>
<subfield code="z">md5:de63a54f5364e3b8c1872f29f9536fb0</subfield>
</datafield>
<datafield tag="909" ind1="C" ind2="O">
<subfield code="o">oai:publish.etp.kit.edu:22080</subfield>
<subfield code="p">user-cms</subfield>
<subfield code="p">user-hardware</subfield>
<subfield code="p">user-etp</subfield>
</datafield>
<datafield tag="653" ind1=" " ind2=" ">
<subfield code="a">CMS</subfield>
</datafield>
<datafield tag="653" ind1=" " ind2=" ">
<subfield code="a">Irradiation</subfield>
</datafield>
<datafield tag="653" ind1=" " ind2=" ">
<subfield code="a">Ionization Chamber</subfield>
</datafield>
<datafield tag="653" ind1=" " ind2=" ">
<subfield code="a">Silicon Sensor</subfield>
</datafield>
<datafield tag="700" ind1=" " ind2=" ">
<subfield code="a">Müller, Thomas</subfield>
<subfield code="u">KIT/ETP</subfield>
<subfield code="4">ths</subfield>
</datafield>
<datafield tag="700" ind1=" " ind2=" ">
<subfield code="a">Goerlach, Ulrich</subfield>
<subfield code="u">CNRS/IPHC</subfield>
<subfield code="4">ths</subfield>
</datafield>
<datafield tag="700" ind1=" " ind2=" ">
<subfield code="a">Dierlamm, Alexander</subfield>
<subfield code="u">KIT/ETP</subfield>
<subfield code="4">ths</subfield>
</datafield>
<datafield tag="700" ind1=" " ind2=" ">
<subfield code="a">Maier, Stefan</subfield>
<subfield code="u">KIT/ETP</subfield>
<subfield code="4">ths</subfield>
</datafield>
<datafield tag="980" ind1=" " ind2=" ">
<subfield code="a">user-cms</subfield>
</datafield>
<datafield tag="980" ind1=" " ind2=" ">
<subfield code="a">user-etp</subfield>
</datafield>
<datafield tag="980" ind1=" " ind2=" ">
<subfield code="a">user-hardware</subfield>
</datafield>
</record>